Results DAEquality LiteOn LTD 163

[edit]
Logfiles of the Analyse program added.
[/edit]

Here are my results of my DAEquality test of my LiteOn Ltd-163 (fw: GH0E) @ 4 speed and max speed, both twice tested.

Can anybody give some comment? Why the differences? Shouldn't I always get the same results for a selected speed?

Note: the same reference cd is used as for the test of my Plextor Px-40ts and LiteOn Ltr-40125s.

4 speed:


Analyse log 1:

Errors total Num : 165934204
Errors (Loudness) Num : 396341 - Avg : -21.4 dB(A) - Max : -2.8 dB(A)
Error Muting Num : 64055 - Avg : 55.4 Samples - Max : 1920 Samples
Skips Num : 37 - Avg : 228.0 Samples - Max : 1632 Samples

Total Test Result : 50.9 points (of 100.0 maximum)

Analyse log 2:

Errors total Num : 83630064
Errors (Loudness) Num : 202477 - Avg : -24.4 dB(A) - Max : -3.3 dB(A)
Error Muting Num : 28902 - Avg : 5.2 Samples - Max : 1920 Samples
Skips Num : 8 - Avg : 6.0 Samples - Max : 6 Samples

Total Test Result : 64.9 points (of 100.0 maximum)


max speed:


Analyse log 1:

Errors total Num : 19591436
Errors (Loudness) Num : 49269 - Avg : -29.2 dB(A) - Max : -7.7 dB(A)
Error Muting Num : 10387 - Avg : 68.5 Samples - Max : 1920 Samples
Skips Num : 14 - Avg : 37.7 Samples - Max : 228 Samples

Total Test Result : 59.8 points (of 100.0 maximum)

Analyse log 2:

Errors total Num : 13393976
Errors (Loudness) Num : 34937 - Avg : -33.1 dB(A) - Max : -7.3 dB(A)
Error Muting Num : 5925 - Avg : 36.5 Samples - Max : 1920 Samples
Skips Num : 6 - Avg : 6.0 Samples - Max : 6 Samples

Total Test Result : 66.6 points (of 100.0 maximum)

Last edited by Upp3rd0G on 25-09-2002 at 16:05