[edit]
C2 output added.
[/edit]
[edit]
Logfiles analyse program added.
[/edit]
Here are my results of my DAEquality test of my LiteOn Ltr-40125s (fw: ZS0N) @ 4 speed and max speed, both twice tested.
Note: the same reference cd is used as for the test of my
Plextor Px-40ts and
LiteOn Ltd-163.
4 speed:
Analyse log 1:
Errors total Num : 322641744
Errors (Loudness) Num : 768240 - Avg : -18.4 dB(A) - Max : -3.4 dB(A)
Error Muting Num : 135588 - Avg : 2.1 Samples - Max : 1919 Samples
Skips Num : 2 - Avg : 1554.0 Samples - Max : 2939 Samples
Total Test Result : 54.9 points (of 100.0 maximum)
Analyse log 2:
Errors total Num : 321426584
Errors (Loudness) Num : 765386 - Avg : -18.5 dB(A) - Max : -2.0 dB(A)
Error Muting Num : 252546 - Avg : 1.8 Samples - Max : 563 Samples
Skips Num : 2 - Avg : 1654.5 Samples - Max : 2939 Samples
Total Test Result : 54.3 points (of 100.0 maximum)
max speed:
Analyse log 1:
Errors total Num : 321652568
Errors (Loudness) Num : 765890 - Avg : -18.2 dB(A) - Max : -5.6 dB(A)
Error Muting Num : 144069 - Avg : 2.2 Samples - Max : 1919 Samples
Skips Num : 1 - Avg : 2939.0 Samples - Max : 2939 Samples
Total Test Result : 54.9 points (of 100.0 maximum)
Analyse log 2:
Errors total Num : 135405996
Errors (Loudness) Num : 322700 - Avg : -18.5 dB(A) - Max : -6.6 dB(A)
Error Muting Num : 39789 - Avg : 1.7 Samples - Max : 371 Samples
Skips Num : 0 - Avg : 0.0 Samples - Max : 0 Samples
Total Test Result : 73.3 points (of 100.0 maximum)
C2 output: